Control Cheks

721 - Class 125 Control Chek Valves

Mueller Steam Specialty


Specification Sheet | Installation

Size: 2 to 14 in. (50-350mm)

Designed for installation in pump discharge piping where it performs triple duty. It acts as a spring loaded silent check valve, a shutoff valve, and a balancing valve. Used in conjunction with the Mueller Steam Specialty suction diffuser, it constitutes a compact and effective complete pump protection and isolation package.

Suction Diffusers

722G - Locxend Grooved End Control Chek Valves

Mueller Steam Specialty


Specification Sheet | Installation

Size: 2 to 12 in. (50 tp 300mm)

Designed for installation in pump discharge piping where it performs triple duty. It acts as a spring loaded silent check valve, a shutoff valve, and a balancing valve. Used in conjunction with the Mueller Steam Specialty suction diffuser, it constitutes a compact and effective complete pump protection and isolation package.

mueller_721.pngmueller_722G.png

1011 - Class 125 Suction Diffuser

Mueller Steam Specialty


Specification Sheet | Installation

Size: 2 x 1 1/4 in to 8 x 12in.

Provide economical and compact pump protection by straining foreign particles and providing proper flow conditions to the pump. This series mounts directly to the suction side of a pump in either the horizontal or vertical position.

1011G - Locxend Grooved End Suction Diffuser

Mueller Steam Specialty


Specification Sheet | Installation

Size: 2 x 1 1/4 in to 12 x 12in.

Provide economical and compact pump protection by straining foreign particles and providing proper flow conditions to the pump.



mueller_1011.png

1012 - Class 300 Suction Diffusers

Mueller Steam Specialty


Specification Sheet | Installation

Size: 2 x 2 in to 12 x 10in.

Provide economical and compact pump protection by straining foreign particles and providing proper flow conditions to the pump. This series mounts directly to the suction side of a pump in either the horizontal or vertical position.





Mueller_1011G.png

Suction Diffuser Rear Strainer Pullout (RSP)

Taco, Inc.


General Information | Specifications | Installation

It is a flow straightening device that provides maximum flow efficiency at the suction inlet of the pump while at the same time reducing space and fitting requirements and eliminating the need for an equivalent length of ten pipe diameters of straight run on the suction side of the pump. It is an elbow (and in some cases a reducing elbow) with a built in strainer that is easily maintained and will provide years of trouble free system performance. It is also offered as a Grooved End Suction Diffuser.

mueller_1012.pngtaco_rsp.png

Don't see what you're looking for? Contact one of our Sales Representatives to see if we have it! Contact Us

Plus Two Multi-Purpose Valve

Taco-HVAC


General Information | CAD Selection Wizard

The "Plus Two" is a Shut-Off Valve, a Non-Slam Check Valve, a Balancing Valve and a Flow Metering Valve, in one versatile package. In addition, you can easily convert the valve from a straight pattern to a 90-degree, right-angle pattern in the field