4900 Series Air Separator

Taco-HVAC


General Information | Performance Curve | CAD Selection Wizard


The Taco 4900 Series Air Separators help you save money and prolong the life of system pumps, piping and components by removing air and dirt from the system to prevent:

Reduced heat transfer
Loss of efficiency
Pipe corrosion
Pump damage
Increased energy consumption
Irritating noise.

taco_8271.png

5900 Series Air Seperator

Taco-HVAC


General Information


Taco's patented 5900 FlexBalance Series Air Separator acts as a hydraulic bridge between the primary and secondary heating and cooling applications. The 5900 Series provides improved system energy efficiency and allows use of smaller pumps for each system circuit.


Constructed of carbon steel materials
Manufactured to ASME Section VIII Div. 1 standards
Energy-saving, Green Building-friendly
Working Pressure: 125 psi @ 270° F
Available from 2" through 12"

taco_5900.png

Vortech Air Separator

Taco-HVAC


General Information


Features Include:
Requires No Minimum Run of Pipe
Convenient 1/2” Bottom Tapping for Installation of Expansion Tank
Cast Iron Body and Cap
Stainless Steel Cartridge and Plate
Viton O-Ring
Available in Sizes 3/4” – 2”.
Maximum Operating Pressure: 150 PSI (1034kPa)
Maximum Operating Temperature: 240º F (115º C)
Recommended Flow Rate: 4 ft./sec.
Maximum Flow Rate: 8 ft./sec.

taco_vortech.png

ACT Tangential Air Separator

Taco-HVAC


General Information


Designed for use in hydronic heating or cooling systems, Taco's compact, highly efficient ACT air separator provides air separation while minimizing space requirements.

Features:
offered with or without strainers
standard pipe line sizes from 2" to 20"
developed for applications with flowrates up to 12,500 gpm
designed for working pressures of 125 psi at 375°F
optional 150 psi maximum pressure units, 375°F maximum temperature units are also available
manufactured from carbon steel listed in ASME Section II

taco_act.png

Air Scoops

Taco-HVAC


General Information


The special design and internal baffles of Taco Air Scoops® slow water velocity to separate the air from solution. Thanks to this design, Taco Air Scoops® efficiently remove air to provide noiseless, air-free hydronic heating, cooling or combination systems.


Features Include:
One-Piece, Cast Iron Construction
Engineered Baffle to Separate Air from Water
Never Requires Servicing
Maximum Operating Pressure: 125 PSI (862kPa)
Maximum Operating Temperature: 300º F (135º C)
Recommended Flow Rate: 4 ft./sec.
Maximum Flow Rate: 8 ft./sec.

taco_scoop.png

Air Vents

Air Vents

Taco-HVAC


General Information


HVAC professionals have recognized Taco Automatic Air Vents as the industry standard for more than 30 years. Attached to the boiler or used through the system, Taco Vents automatically purge unwanted air from any hydronic installation, allowing the system to run more efficiently.

87_2978.jpg

Buffer Tanks

Buffer Tanks

Taco-HVAC


General Information


Buffer tanks are often employed within HVAC systems to provide additional system fluid volume in order to prevent short cycling of heating or cooling apparatus. Taco offers these tanks in sizes from 50 gallons up thru 1050 across 16 tank volumes. Each of these tank models are available with system connections on the side of each tank located either high or low to meet application requirements. To meet the wide scope of job site specific connection sizes specified these tanks are available with a standard range of connection sizes as shown on our submittal data sheets.

taco_buffer_5525.png

Don't see what you're looking for? Contact one of our Sales Representatives for more information. Contact Us

For more information about our Air Separators, Air Vents, and Buffer Tanks contact a Sales Representatives.